Dt-500cmn Superior Fireplace User Manual

If your fireplace manual is missing, we can help. Fireplace remote control manuals are easy to misplace or accidentally destroy. If your owner’s manual is missing, you’ve come to the right place. We’ve gathered links to most of our top fireplace remote controls below. We’ve also included manuals for several other common fireplace. Manuals and free owners instruction pdf guides. Find the user manual and the help you need for the products you own at ManualsOnline.

Installation and Operating Instructions

Mendota Gas Fireplace Inserts

FullView Insert

Superior

FV33i Gen 3 FullView Gas Fireplace Insert - Installation & Operating Manual
FV44i Gen 3 FullView Direct Vent Gas Fireplace Insert Heater with Remote Control - Installation & Operating Manual

Décor Insert

FV33i Décor Gen 3 FullView Gas Fireplace Insert - Installation & Operating Manual
FV44i Décor Gen 3 FullView Direct Vent Gas Fireplace Insert Heater with Remote Control - Installation & Operating Manual

Dt-500cmn Superior Fireplace User Manual

D Series Insert

D30 - No Remote - Installation & Operating Manual
D40 - No Remote - Installation & Operating Manual

Mendota FullView Zero Clearance Gas Fireplaces

Landscape

FV36 with Remote Control PF2 - Installation & Operating Manual
FV36 Décor/Timberline with Remote Control PF2 - Installation & Operating Manual
FV42 FullView Gas Fireplace - Installation & Operating Manual
FV48 FullView Gas Fireplace - Installation & Operating Manual

Linear

ML39 (AA-11-04391) Installation and Operating Manual - Flush-Faced Glass - Compatible with LED Floor Light Kit
ML47 (AA-11-04390) Installation and Operating Manual - Flush-Faced Glass - Compatible with LED Floor Light Kit
ML54 Installation and Operating Manual - Compatible with LED Floor Light Kit
ML60 Installation and Operating Manual - Compatible with LED Floor Light Kit
ML72 Installation and Operating Manual - Compatible with LED Floor Light Kit

Square

FV34 with Remote Control PF2 - Installation & Operating Manual
FV34 Timberline/Décor with Remote Control PF2 - Installation & Operating Manual
FV34 Arch Traditional PF2 - Installation Manual
FV41 with Remote Control PF2 - Installation & Operating Manual
FV41 Timberline/Décor with Remote Control PF2 - Installation & Operating Manual
FV41 Arch FullView Gas Fireplace - Installation Manual
FV46 with Remote Control PF2 - Installation & Operating Manual

Mendota DXV Series

DXV35 TimberFire, Manual Control - Installation & Operating Manual
DXV35 Deep Timber 4 with Manual Control - Installation & Operating Manual
DXV35 DT4 LX Direct Vent Gas Fireplace Heater with Remote Control - Installation & Operating Manual
DXV42 TimberFire with Manual Control - Installation & Operating Manual
DXV45 DT4 LX Direct Vent Gas Fireplace Heater with Remote Control - Installation & Operating Manual
DXV60 Direct Vent Gas Fireplace Heater with Manual Control - Installation & Operating Manual

Mendota Designer Series

M27 Chelsea, Manual Control - Installation & Operating Manual
M50 Greenbriar, Manual Control - Installation & Operating Manual

Mendota Heat Management

Mendota Cool Wall Kit Installation Instructions
Mendota FlexHeat Installation Instructions
Mendota VersiHeat Installation Instructions

How to Operate a Gas Fireplace

Gas fireplaces are available in both natural-gas styles and provide the comfort and warmth of a traditional fireplace without the hassle of chopping wood. Most systems are installed so they vent to the outside. That keeps carbon monoxide from building up in your home and makes them safe to operate.

Igniting with a Fireplace Key

  1. Look over the user manual included with your fireplace. Every fireplace is different, so check your model’s user manual before lighting or adjusting it. While the ignition method will most likely be similar, knowing the ins and outs of your specific fireplace will help you avoid any dangerous, and possibly even lethal, accidents.

    • Contact the fireplace’s manufacturer if you do not have a copy of the user manual.
  2. Remove your fireplace’s outer cover. For both safety and aesthetic reasons, gas fireplaces come with a front cover separating the fire chamber from the rest of the room. To ignite the pilot light, you’ll need to open or completely remove this cover. These panels are typically made of glass, so lay yours in a safe area to prevent unnecessary damage.

    • In most cases, you can remove a gas fireplace cover by simply pulling it off the device.
  3. Put a fireplace key into the device’s gas valve knob. To ignite your device’s pilot light, you’ll need to insert a fireplace key into the gas valve knob located to the left or right of the fireplace. Once you insert the key, do not turn it until after preparing your lighter, otherwise you may release a dangerous amount of gas into the room

    • Some fireplaces may have this key permanently installed in the wall.
    • If you do not have a key, you can purchase a replacement at most home improvement stores. Make sure to check your user manual to see what kind of key the fireplace takes.
  4. Hold a long lighter up to the burner and ignite it. Before turning the gas valve knob, grab a lighter with a long enough head that you can insert it into the fireplace while keeping your hands away from the fire pit completely. Then, place the head of the lighter next to the device’s burner and pull the lighter’s fuel trigger. Be prepared to move your hands back quickly if the pilot light ignites unexpectedly.

    • For safety, put on heat resistant gloves before operating the lighter.
    • If you do not have a long enough lighter to safely ignite the fireplace, insert a lit match next to the burner instead.
    • Depending on how far away the gas valve knob is, you may need to have a friend hold the lighter or operate the key.
  5. Turn the gas key. With the lighter activated, move the gas valve knob about half a turn counter-clockwise. This will release gas into the fireplace, causing the pilot light to ignite. Be prepared to move back quickly in case the fire ignites stray gas particles and flares out into the immediate surrounding area

    • If you smell a small amount of gas, remove the lighter and open your windows and doors to air the room out.
    • If you smell a lot of gas, remove the lighter and exit the house immediately. Then, contact your natural gas provider. If neither are available, contact 911 or your local fire department.
  6. Replace the fireplace’s outer cover immediately. To keep any excess gas from escaping into the room, cover your fireplace with the front panel you removed earlier. Once the cover is secure, you can safely control the fireplace using the gas valve key, turning it counter-clockwise to increase the flames and clockwise to decrease them.

Lighting with a Control Panel

  1. Read your fireplace’s user manual thoroughly. Before lighting or adjusting your fireplace, read the included user manual thoroughly. Though most fireplaces use similar ignition methods, yours may have a specific element or feature that, when handled improperly, could be dangerous.

    • If you do not have a user manual, check online or contact the fireplace’s manufacturer to get a copy.
  1. Locate and open your fireplace’s control panel. Most modern gas fireplaces come with a specialized control panel that manages the fixture’s pilot light. For aesthetic purposes, you’ll typically find this panel hidden behind the fireplace’s front screen, which you can open or remove to gain access.
    • On most gas fireplace models, you can remove the screen by simply tugging it off the device.
  2. Turn the control knob to the off position for at least 5 minutes. Look for a knob on your control panel with the words On, Off, and Pilot on it. If the knob is not in the off position, turn it so that it is. Then, let your fireplace sit for at least 5 minutes, allowing any excess or lingering gas to clear out.

    • If you smell a faint amount of gas, open your windows and doors to ventilate the area.
    • If you smell a large amount of gas, leave the house immediately and call your natural gas provider. If you can’t get a hold of either, call 911 or your local fire department.
  3. Twist the shutoff valve until it is parallel with the gas line if necessary. Most fireplace manufactures attach a shutoff valve to the device’s gas line, giving you greater control over your natural gas output. If your fixture comes with 1 of these valves, make sure to move it until the handle sits parallel to the gas line, allowing fuel to enter the fireplace.
  4. Move the control knob to the pilot position. This will give you access to the device’s pilot light, or the small flame that helps the fireplace burn. To avoid any hazardous mistakes, do not twist the knob until you are ready to ignite the pilot light.
  5. Press the control knob down and hit the ignition switch. To ignite the pilot light, press your finger into the center of the control knob and hold it in place. Then, hit the fireplace’s ignition switch, which is typically a red button located near the control knob. Tap the switch until the pilot light ignites.

    • If the pilot light fails to ignite after multiple attempts, restart the entire process and try again. If it continues to fail, check for any common ignition problems or call a professional for help.
  6. Hold the control knob down for at least 30 seconds. To keep the flame alive, you’ll need to hold the control knob down for a minimum of 30 seconds, possibly even longer. This will give the thermocouple, a safety device that stops the gas flow if the pilot light shuts off, a chance to heat up and register that the pilot is back on.
  7. Move the control knob to the “on” position. With the pilot light ignited, turn your fireplace’s control knob from the pilot position to the on position. This will make sure the pilot light stays on indefinitely, allowing you to activate the fireplace whenever you wish using the device’s wall switch or remote control. When you’re finished, remember to replace the fireplace’s front screen if you had to remove it.

    • Be aware that, while a power outage should not affect your fireplace’s pilot light, it may deactivate any switches regulating the gas output.

FAQs

Should the chimney vent be open when the logs are turned on?
Yes. Burning logs produces carbon dioxide as well as carbon monoxide, so the open vent is needed to get these harmful gases out of the house.

Will the wall switch light the fireplace when the power goes off?

Dt-500cmn Superior Fireplace User Manual Instructions

No. The wall switch sends an electrical signal to your fireplace to open a valve and release the gas for the pilot light to light it. Without power most fireplace valves will not open.